1 EXPANDABLE MOBILE TRAILER; TECHNICAL SPECIFICATIONS
1.1 the main chassis and trailer of the platform opened, the load specified as carrying capacity working
it will carry with safety in its conditions and no deformation will occur.
it will be designed in strength and style.
1.2 Jost foot
1.3 acrylic paint
1.4 2017 tire model
1.5 2017 model wheel
1.6 WABCO brake valves
1.7 WABCO EBS Braking System
1.8 en 2.460 internally
1.9 length 13.50 out of dips
1.9 hat 700 hair
1.11 floor tile 30 mm imported hair + plywood quality material
1.12 latest system technology
2. UPPER STRUCTURE
2.1. Panels and roof
2.2. Deluxe Room
2.3. Floor
2.4. Pop - up platform
2.5. Electrical system
2.6. Lighting
2.7. Generator
2.8. Air Conditioning-Ventilation
That's 2.9. Paint
2.10. Stairs
It's 2.11. Electronic audio and light equipment
2.12.Trailer platform will be monolithic. It won't be removable. Trailer trailer with tow truck
providing proper maneuverability even if the axis is at a 90º angle
it will be in structure.
3. HYDRAULIC EQUIPMENT
3.1.To operate the hydraulic system, there will be a 250 lt oil tank.
3.2.3 kW monophase motor will be available to operate the hydraulic system.
3.3.Oil pressure hydraulic pump to ensure the most article 12/3.
3.4 there will be flow dividers and return brake flow dividers to remove the side interior and exterior cover.
13.5 the return quad flow divider will be used to balance the floor of the platform.
4. COMMAND BOARD
4.1 the steel will be manufactured with a lock cover.
4.2 control panel manual 4-group hydraulic control arms will be. the four-group control system will be used in the opening of the upper and inner doors.
4.3.It will be a pressure gauge.
4.5.Trousers, breeches etc. (for women) the elements will not be damaged even under high current.
5. ELECTRICAL EQUIPMENT
5.1 units can be used with hammers with 24 v DC system voltage. The electrical system of the units shall be designed in such a way that it does not require any changes to the electrical equipment during use.
5.2 there shall be five side lamps on each side and at least two reflectors on each side.
5.3 .In the rear bumper of the unit, it will be equipped with stop, tail turn and signal lamps in accordance with traffic laws and regulations. Signal lamps will be in the enclosure. It will be reflective material for warning purposes.
5.6 all elements to be used in electrical system shall comply with the relevant standards.
5.7 the cables in the system will be passed through the appropriate protectors. Separate cables
it will be used.
6.PAINT AND EXTERIOR SURFACE COATING
6.01 all units and parts of trailers with sandblasting method or chemical materials
it will be cleaned and covered with the foliage determined by the administration at the final stage.
7. DRESSING
7.01 the design to be determined by the administration shall be covered with party logos and articles and folio.
8. FLOOR
8.1 all wood material used in the pop-up platform will be playwood material.
It will be resistant to humidity and heat. Air gap between structural elements and pavement
will be found.
8.2. The existing floor will be covered with 18 mm water plywood.
8.3 the floor covering will be permanently placed on the floor, completely covering the working area of the sections and there will be no missing space. Coated material will be water resistant and material. The floor coating should be non-asbestos-free, non-slip, anti-bacterial, water-washable and hygienic, resistant to heat and chemicals.
9. OPENING ROOM TRAILER
2.4.1. Opening platform side door opening from right side up to 90 with hydraulic from the beginning
it'il open up. Inner door opening from top to bottom with hydraulic from top to bottom 90 degrees
it will open.
2.4.2. The top cover length is up to 10.00 CM. width 2.80 CM.
2.4.3. The floor length of the platform is up to 9 mt. Width 2.50 CM. it will be,
2.4.4. 18 mm water contract will be installed on the floor.
2.4.5. The roof height of the platform is 4 m from the floor. The floor of the pop-up platform, the ceiling height range of the pop-up platform is at least 2.30 CM. .
2.4.6. The height of the drop-down platform can be increased and adjusted with the clamping arms between 130 cm and 160 cm from the ground.
2.4.7. The drop-down platform height adjustment will be supported with adjustable feet
2.4.8. The pop-up platform should be prepared so that it can hang around in vinyl.
10. ELECTRICAL SYSTEM
10.1 the electrical system shall be manufactured and installed in accordance with the relevant Highway Traffic Law, Vehicle Manufacturing modification Assembly regulation, whether or not the specified equipment, other special accessories and cables, including the main tables of the unit's (pop-up platform vehicle) are specified in this specification. The electrical system will include the necessary light and audible stimuli. All
electrical systems should be placed in such a way that the fuse and switches can be removed easily.
External enclosures of lamps electronic devices and connections are corrosion resistant
you must have.
10.2 electrical network; electrical circuits of electrical equipment and accessories in the unit
the chassis of the car should be completely separate and different from the circuits. Used
conductors must be insulated with high heat resistant thermo plastic or the same material. Conductors must be permanently marked or undamaged for recognition. These conductors must either be in a non-flammable braided system at high temperature or in isolation channels that delay heat. Cables and ducts will be identified as good ways to prevent sagging and wear. There should not be any cables in the open, all cables can be easily removed from the inside of the wall as needed.
it will be moved to be modified. The folds and holes in the system, passing
it will be shaped in a manner appropriate to where it is used to protect and detect the conductors.
10.3 installation; all electrical equipment except switchgear, switches, exit channels, etc.s must withstand a current up to 125% of the maximum current to be carried by the circuit to be placed. In installations, thin enamel wires from 0.65 mm2 will not be used (sockets and sockets).
lighting elements and all kinds of installations 1.5mm2 and 2.5mm2 lik cables
nutrition)). Protection from weather conditions to prevent corrosion on ports
measures must be taken and all terminals must be numbered and coded in such a way that they do not break down.
The ports should be within easy reach for inspection and control. The unit
electrical installation an automatic main switchboard (distribution table) and separate for each circuit
it should be an automatic shut-off switch. Automatic fuses should be bipolar. Main panel
current protection relay must be present at the output.
10.4 device feeds to be used in the vehicle in the interior cabin considering (each
the number of sockets will be determined (so that the device will be supplied from an independent socket).
3 sockets will be installed, in addition to the other parts of the device supply sockets
(if available) one plug will be installed.
10.5 . Each section inside the vehicle and the entrance of the vehicle will work with 220V AC
it will be illuminated. For this purpose, appropriate lighting installations and light bulbs and facilities
10.6 all kinds of metallic elements in the vehicle will be protected against voltage leakage and necessary measures will be taken by the company. The administration may propose additional measures if necessary, and any measures that may endanger life safety shall be taken.
10.7 any material to be used will be produced according to Tse Li or equivalent standards.
11. LIGHTING
11.1 luminaires that will illuminate the opening platform will be equipped with LED system so that it is not visible from the outside.
12. AIR CONDITIONING, VENTILATION
Air conditioning will be added to the pop-up platform upon request. It can be fixed or mobile.
13 stairs
13.1.2 pieces, both entrance to the inner room by the side of the trailers and exit to the platform
13.2 .It should be easily and safely designed and made of aluminum material suitable for landing.
13.4 ladder 30 mm x 30 mm at least 2 mm thick steel profiles will be made.
13.5 the steps of the stairs will be made of non-slip aluminum material.
13.6. The ladder will be made of folding type and easy to carry.